Loading the 3D sheave load force simulator…

Feeding sheave maximum pulling loads (lb)

Merchant-supplied ratings. Angle of pull: 15°–90°. These are cable pulling limits, not resultant sheave forces. Verify the complete rigging setup and product instructions. Between listed angles, the simulator uses the next higher angle’s lower pulling limit. It assumes full cable tension at each sheave; it does not estimate friction losses.

Angle 441-2 441-2-1/2 441-3 441-3-1/2 441-4 441-5 441-6
15° 1,750 1,900 6,050 8,000 8,000 8,000 8,000
30° 900 1,000 3,150 5,500 7,000 8,000 8,000
45° 650 700 2,200 3,550 5,200 7,400 7,400
60° 500 550 1,800 2,900 4,200 6,000 6,000
75° 450 500 1,600 2,600 3,650 5,500 5,500
90° 450 500 1,550 2,500 3,500 5,250 5,250

The 3½-inch model is included in this reference table; a matching 3D model is not currently available in the simulator.